Consulting ServicesMiller CTWContact
< Back To Login | Order Form

Equipment Specifications - Controlled Temperature
Warehouse Monitoring

Balance Engineering Inc. offers custom design, application and analysis of temperature, pressure flow, and power monitoring systems.

We offer the exclusive auto dial-out, remote download and analysis services.

Balance Engineering, Inc. is the recommended supplier of the automated temperature monitoring equipment and monthly reporting services.  We offer two (2) service options as listed below.  In either option, the equipment configuration is a single logger serving up to four (4) temperature sensors.  Sensors can be located up to 150 feet from the logger.  The accuracy of the logger and sensor combined is +/-0.4 °F.  Only one (1) monthly download is required to capture data for all four sensors per logger.  Additional loggers can be networked if required for larger facilities.

Service Options

Option 1 - Monthly Monitoring Service - Recommended Option

Balance Engineering, Inc. Will preprogram logger(s), package all necessary accessories and ship to warehouse location for client installation.  On a monthly basis, Balance Engineering will automatically download temperature data, generate customized report, and send report via E-mail and to client and sales manager.  Technical assistance provided via E-mail and phone during installation and startup.  Three (3) year service agreement required.  No upfront equipment charges.  (Security deposit required.)  Client billed quarterly for service.

Option 2 - Equipment and Technical Assistance Only

Balance Engineering, Inc. Will preprogram logger(s), package all necessary accessories and ship to warehouse location for client installation.  Technical assistance provided via E-mail and phone during installation and startup.  Client billed upon shipment of equipment.

Order Form

Equipment

4 Channel Logger

Logger Setup Screen

 

Remote Temperature Sensors

PT907

White epoxy tip.  Parallel bonded 28 gage wire with PVC insulation.  0.112" maximum diameter. 
Not rated for immersion.

Temperature range:

-50 to 105°C (-58 to 221°F)

Lead length:

4 feet (1.2 m)

Interchangeability:

±0.1°C from 20 to 45°C (68 to 113°F)

 

PT940

Similar to the PT933 Probe, but features a polyolefin jacket bonded to probe and cable to form
a moisture-proof barrier.  Suitable for soil temperature applications and wet environments.

Temperature range:

-50 to 105°C (-58 to 221°F)

Lead length:

20 feet (6.1 m)

Interchangeability:

±0.1°C from 0 to 70°C (32 to 158°F)

 

PT916

Closed end stainless steel tube, 1/8" dia. by 4" long.  24 gage Teflon insulated leads.  Suitable for liquid or gaseous immersion, refrigeration (inserts into a Pete's Plug), and general temperature applications.

Continuous temperature:

-50 to 120°C (-58 to 248°F)

Intermittent maximum:

302°F (150° C)

Lead length:

3 feet (.9 m)

Interchangeability:

±0.1°C from 0 to 70°C (32 to 158°F)

 

CF916-1/8

Optional bored-through stainless steel fitting for PT916 probe.  1/8 NPT male threads.

 

Relative Humidity & Temperature Probe

Uses two Pocket Logger channels.  A total of two RH & Temp.  Probes may be connected to one Pocket Logger.  Relative Humidity data is easily converted to Wet Bulb or Dew Point with a mouse click.

Operating temperature:

-40 to 85°C (-40 to 185°F)

Humidity Range:

0-95% R.H.

Accuracy:

±2% R.H. from 0 to 95% RH

Stability:

±1% R.H. typical at 50% RH in 5 years

Hysteresis:

±0.8% of span maximum

Linearity:

±0.5% R.H. typical

Repeatability:

±0.5% R.H.

Physical:

Rugged housing with sintered SS filter

Size:

0.5" dia x 2.5" long (13mm x 64mm)

Temperature Accuracy:

see specifications, page 11

Interchangeability:

±0.1°C from 0 to 70°C (32 to 158°F)

Part No:

(available in 3 lead lengths)

TRH-100

(12" leads)

TRH-100-10FT

(10 ft shielded cable)

TRH-100-20FT

(20 ft shielded cable)

 

Light Sensor

Connects directly to any Pocket Logger Channel.  Wide dynamic range.  Low cost.  0.3 dia., 2.5" length, integral shielded cable.

Operating Temp:

-30 to 70°C (-22 to 158°F)

Physical:

Thermoplastic lens and housing

Part No:

LS100-4FT

(4 ft / 1.2 m cable)

LS100-15FT

(15 ft / 4.5 m cable)

 

Logger & Sensor Specifications

Size:

4.70" x 2.40" x .93"; (120 x 61 x 24 mm)

Weight (with battery):

6 ounces; 156 grams

Case material:

Impact resistant ABS Plastic

Operating limits:

-40 to 60°C (-40 to 140°F). 5-90% R.H. (non-condensing).

Clock accuracy:

+/-2 min per month (-10 to 50°C).

Battery:

9 volt (user replaceable)

Battery life:

Est. 1-3 years of continuous operation depending on sampling rate; battery voltage displays on PC.

Data Retention:

Over 200 years with no power.

Data rate:

9,600 baud.

Number of channels:

Four

Starting modes:

Start at pre-set time and date, Start when Channel 1 sensor is attached.

Running Modes:

Running continuous (memory wraps around).

Sampling modes: Three

Single point, Average (accumulate readings every 2 secs; compute and store average value), or Pulse Counting (maximum pulses per sample interval: 8 bit: 255, 10 bit: 1023, 12 bit: 4095). 2

Sampling rates:

1 hour.

Real time display:

Channel readings updated every 2 secs on PC; can be active while recording.

Input termination:

Removable screw-type terminal block.

Input impedance:

Greater than 5 Megohm (when sampling).

Input protection:

Over/under voltage, 40 amps peak 8/20 us

MEASUREMENT RESOLUTION

12 BIT RESOLUTION

Memory capacity:

21,504 readings (86,016 with -M option)

Temperature accuracy: 4

±0.15°C from 0 to 40°C.

(logger + probe)

(±0.27°F from 32 to 104°F).

±0.3°C from -25 to 85°C.

(±0.55°F from -13 to 185°F).

Voltage input accuracy:

±0.25% of full scale.

Resolution:

0.025°C from 0° to 40°C.

0.063°C or better from -25 to 75°C.

0.125°C or better from -45 to 100°C.

0.025% of full scale.

Available Sensors

Over 25 direct-connect sensors are available for the Logger including Temperature, Pressure, Light, Humidity/Dew Point, AC Current and AC Voltage.  Sensors may be mixed and matched in any combination.  See accessories for details.

Input Ranges:

Inputs auto-configure for sensor or input range selected in software and include 0-5vdc. 2 wire resistance (30k ohm midpoint), and 3 wire resistance (minimum 2k ohm).  Plug-in modules are available for millivolt inputs, +/-5vdc, 0-10, 0-20, 0-30, 0-60vdc and 4-20 ma.

Approvals:

Logger is CE approved to EN50081-1 (RF) emissions) and EN50082-1 (ESD and RF immunity).

Warranty:

Logger is backed by a 3 year limited warranty.  Accessories are backed by a 1 year limited warranty.

Notes:

4 Assumes use of PT900 series temperature probes.

Specifications subject to change without notice.

 